Grow Room Fan CFM Calculator
Exhaust fan size in CFM to exchange a grow tent or room's air on schedule.
Use ToolFree calculator
Vapor pressure deficit from temperature and humidity using Tetens' equation, with stage-appropriate kPa verdicts for tents and rooms.
Chlorova · updated for 2026
Quick samples
Click “Calculate” to see your results.
VPD is computed at canopy temperature and canopy humidity, and thermometers strapped to a wall or a fan duct read neither, so mount your sensors at the growing tips before trusting any number here. Tetens' equation is the standard horticultural approximation and agrees with full saturation tables within a few percent across normal grow-room ranges, drifting slightly at temperature extremes. Deficit is a steering input, not a destination: plants drink and feed along the gradient, and pushing VPD to force transpiration also concentrates salts at leaf edges and inflates every CO2 and nutrient calculation beside it.
Vapor pressure deficit is the single number that tells you whether your canopy is breathing or suffocating, because it measures not how much water is in the air but how badly that air is still hungry. This calculator takes a temperature and a humidity reading, runs the standard Tetens equation for saturation pressure, and returns the deficit in kilopascals with a stage-appropriate verdict. It is the reading that lets one dial, not two, steer transpiration, feeding, and mold risk in a tent or greenhouse.
First the conversion: a Fahrenheit entry is scaled by five-ninths and shifted to Celsius, while Celsius passes through untouched, because the vapor pressure math wants the metric. Tetens then answers how much water a degree of air could hold, 0.6108 times e raised to 17.27 times the Celsius temperature over that temperature plus 237.3, giving the saturation vapor pressure in kilopascals.
The deficit is what the humidity did not fill: saturation pressure times the fraction of air still hungry, one minus relative humidity. At 22 degrees and 60 percent, saturation reads 2.65 kPa and the air is pulling 1.06 of it off every wet leaf. Inches of mercury are offered alongside because many analog gauges still wear that scale, and a blank or over-100 humidity returns dashes rather than a fake verdict.
Common grow-room VPD working ranges by stage, the same bands the verdict reads, with the tent-standard 72 to 78°F pairing that delivers them. Canopy-level readings are the honest ones, so take sensors to the growing tips before comparing any row of this table.
| Stage | kPa range | inHg | Classic pairing |
|---|---|---|---|
| Clones and seedlings | 0.4-0.8 | 0.12-0.24 | 70-75°F, 65-75% |
| Early vegetative | 0.8-1.0 | 0.24-0.30 | 70-74°F, 55-65% |
| Late vegetative | 1.0-1.2 | 0.30-0.35 | 72-78°F, 50-60% |
| Flowering | 1.0-1.6 | 0.30-0.47 | 72-78°F, 45-55% |
| Late ripening | 1.2-1.5 | 0.35-0.44 | Humidity floor for mold |
Use it any time the tent feels wrong and the thermometer and hygrometer disagree about why, since the deficit resolves the argument in one number. It reads air, not roots, so pair it with the reservoir and EC tools for feeding decisions, and let the fan CFM calculator size the ventilation that keeps these readings honest.
Vegetative growth runs best near 0.8 to 1.2 kPa and flowering 1.0 to 1.6, with clones and seedlings much gentler at 0.4 to 0.8. Those bands assume canopy-level readings, which is why a sensor at the growing tips beats one clipped to the wall.
Compute the saturation vapor pressure for the temperature with the Tetens equation, then multiply by one minus relative humidity. That product is the deficit, and this page does the exponential so you only enter two readings.
Extremes fail differently: too high closes stomata and stalls growth while concentrating salts at leaf margins, and too low turns the canopy into a humid mold incubator with barely any nutrient pull. Most tents err low in winter and high under hot lights.
It drives every plant everywhere, but outdoors you manage it by shading, mulching and windbreaks rather than dials. Greenhouse growers do steer it seriously, which is where the vent-fog logic of the stage bands came from.
Because the horticulture industry long paired analog humidity-temperature charts to the old inHg scale, and many combined meters still print it. The page converts the same deficit into both units so the reading and the math line up.
Yes, gas and deficit are a pair, because elevated CO2 lets plants keep stomata partly closed, which means slightly higher VPD can be tolerated without shutdown in a dosed tent. Enrichment without the deficit math is just expensive leakage.
Chlorova Gardening Team
Builds, checks and documents every tool we publish
Chlorova editorial review
Checked against extension-service publications
Exhaust fan size in CFM to exchange a grow tent or room's air on schedule.
Use ToolConvert nutrient EC to ppm across 442, 500 and 700 scales.
Use ToolWet substrate weight, flush yield, pasteurization hours by method and a colonization finish date for a dry-weight recipe.
Use ToolCalculate solute and total water potential from the van 't Hoff relation, in bars, megapascals and psi, with a water-movement verdict.
Use Tool