Watering Needs Calculator
How many gallons your garden bed needs each week.
Use ToolFree calculator
Convert nutrient EC to ppm across 442, 500 and 700 scales.
Chlorova · updated for 2026
Quick samples
Click “Calculate” to see your results.
ppm is not a universal unit — it is EC wearing a scale's assumption about which salt the water contains. Always record the scale alongside any number; nutrient charts that say 'ppm' without a scale are ambiguous by definition.
The EC to ppm converter translates between the two languages of hydroponic nutrient strength — electrical conductivity (mS/cm) and parts-per-million — across the three conversion scales that meters actually use: 442 (potassium chloride), 500 (sodium chloride) and 700 (general). The same reservoir reads 1,250 ppm on one meter and 1,750 on another, which is why charts that quote ppm without naming a scale start fights in grow forums. Enter either number, pick your meter's scale, and both sides of the translation appear together, with a typical-EC range for your crop as the sanity check.
One multiplication and its inverse: ppm = EC × scale factor, and EC = ppm ÷ scale factor, where the factor is 442, 500 or 700 ppm per mS/cm. Each factor is really a statement about salt: a solution of potassium chloride conducts about 442 ppm-equivalent per mS, sodium chloride about 500, and the cheap general-purpose convention claims 700 as a rough 'all salts' average.
EC itself measures how much current the solution carries, which correlates with total dissolved ions — the nutrient load — without knowing what they are. That is why the scale exists at all: the meter sees conductivity, and the ppm number is the meter's guess at a weight. The guess is calibrated for one salt type; a hydroponic mix of nitrate, phosphate and potassium salts behaves closest to the 500–700 range in practice, which is why lab convention and budget meters disagree so cheerfully.
Each scale converts one EC to a different ppm claim. None is 'right' — they answer different questions about the salt in solution, and the only sin is mixing them silently.
| Scale | Basis | 1.0 EC reads | Typical users |
|---|---|---|---|
| 442 | KCl solution | 442 ppm | Blum, Eurofertil, EU labs |
| 500 | NaCl solution | 500 ppm | Apera, lab convention |
| 700 | General TDS | 700 ppm | Budget TDS pens, US retail |
Use it any time a number crosses between a meter, a chart and a friend — that is, every conversation about nutrient strength. It is not a substitute for measuring at all: tap water with high sodium reads an EC that flatters nothing about its fertility, and foliar sprays and soil feeds are planned by product rate, not reservoir EC. For building a feed recipe from scratch, this converter checks the strength; the actual salt math lives in the nutrient formulation tables your supplier publishes.
The one your meter uses — that is not a choice but a fact to look up. When choosing a new instrument, 500-scale EC meters match lab convention and most modern charts, while 700 ppm pens match the legacy American advice that still circulates.
Only if the scale matches. A 1,000 ppm reading on the 500 scale is 2.0 EC and 1,400 on a 700 meter, while 1,000 on the 700 scale is 1.43 EC and 715 on a 500 meter. Always ask 'which scale?' before comparing feed strengths.
Because EC is the actual measured quantity and ppm is a derived claim about salt composition. As meters standardized on EC display, chart-makers dropped the ambiguous unit — the conversion belongs to the meter, not the recipe.
It is a meaningful baseline, not a verdict: at 0.5–0.7 EC of incoming water you simply start closer to crop limits, and many growers cut it with RO or dose lower. Test the drain EC after a week before deciding it is a problem.
Weekly in active use, with fresh standard solution, and before any important decision if it has been bumped or its battery dipped. A drifting EC meter turns every downstream number — this converter included — into a confident wrong answer.
About two percent per degree Celsius of conductivity, so a reservoir ten degrees cold reads roughly twenty percent low. Meters with ATC correct it automatically; without, sample at room temperature.
Chlorova Gardening Team
Builds, checks and documents every tool we publish
Chlorova editorial review
Checked against extension-service publications
How many gallons your garden bed needs each week.
Use ToolDaily light integral from PPFD and hours — and the runtime or intensity a crop needs.
Use ToolTurn a soil test into pounds of nutrients per bed.
Use ToolCalculate solute and total water potential from the van 't Hoff relation, in bars, megapascals and psi, with a water-movement verdict.
Use Tool