Grow Light DLI Calculator
Daily light integral from PPFD and hours — and the runtime or intensity a crop needs.
Use ToolFree calculator
How many grow lights, fans and pumps safely fit on a 15 A or 20 A circuit.
Chlorova · updated for 2026
Quick samples
Click “Calculate” to see your results.
The 80% continuous-load rule is a US NEC convention (NEC 210.20(A)) — different countries use different factors and this tool assumes a nominal 120 V. Ballast and driver inrush, daisy-chained power strips, and long extension cords can trip a breaker even when the steady-state number looks safe, so treat this as a starting point and add real margin for anything on a shared circuit.
The grow tent circuit breaker calculator answers the question that trips breakers and cooks drivers: how many light fixtures, fans and pumps you can safely run on a 15 or 20 amp branch circuit. It applies the electrician's continuous-load rule — a circuit should not sit above 80% of its breaker rating for hours at a stretch, which is exactly how grow lights run — and turns fixture wattage into the maximum number that fits. The output is a shopping-list number: fixtures per circuit, amps each draw, and the total safe watts, so tent builders stop finding out by a midnight trip.
Amps = watts ÷ 120 for US nominal voltage, so a 600 W light draws about five amps. The National Electrical Code calls anything running three or more hours continuous, and a grow circuit always is, so the working ceiling is 80% of the breaker: 12 A on a 15 A circuit, 16 A on a 20 A. Convert to watts by multiplying again by 120 — 1,440 W and 1,920 W respectively — and divide by the fixture watts to see how many fit.
Ballast and driver losses count: a '600 W equivalent' LED that actually pulls 320 W at the wall is the 320 figure to use, not the marketing number, and magnetic-ballast HPS fixtures add another 10–15% on top of their lamp watts. The 80% rule exists because breakers heat up over hours, and a 15 A breaker sitting on a true 15 A load can nuisance-trip after an hour or two even though the math looks fine at second zero. Rooms on overnight timers with no one to reset are where this bites.
At nominal 120 V, US NEC continuous rule of 80%. Compare your tent's total running watts against the safe figure — not the maximum — for the circuit you're on, remembering that most bedroom and living-room circuits are 15 A while kitchens and garages are often 20 A and already shared with other outlets.
| Breaker | Max amps | Safe amps (80%) | Safe watts |
|---|---|---|---|
| 15 A | 15 A | 12 A | 1,440 W |
| 20 A | 20 A | 16 A | 1,920 W |
Use it whenever you are speccing or expanding a tent and want to know whether a fixture combination fits the outlet you're actually plugged into. It is a US 120 V model — for 240 V systems, three-phase panels, or dedicated circuits from the breaker box, work with a licensed electrician instead. For short duty-cycle equipment like a shop vacuum or tiller, skip the 80% continuous rule entirely; a momentary load at 100% is fine. And when a room grows past one 20 A branch, the answer is a second circuit, not a bigger breaker on the same wire.
Under the continuous-load rule, 1,440 watts — so fourteen 100 W bars, seven 200 W fixtures, or a single 600 W HPS plus a couple of small fans. This assumes nothing else shares that breaker; kitchen circuits, refrigerators and space heaters all eat into the same number.
Because anything running three or more hours heats a breaker up enough that its bimetallic strip will trip even at a nominal-max current, and the NEC calls that continuous load. Sizing at 80% is the standard margin so an overnight photoperiod does not nuisance-trip while nobody is home to reset the panel.
Not usually, and the direction depends on the marketing: some bars advertise an 'equivalent' number far higher than the actual draw, others quote diode watts without the driver loss. Trust the wall-plug running-watts figure from the spec sheet or a plug-in meter, since that is what the breaker sees.
Sometimes, but only if the combined running watts stay under the safe continuous figure. Two 200 W LEDs plus fans and pumps on a 20 A kitchen-rated circuit sit comfortably near 800 W of the 1,920 W budget, but two 600 W HPS fixtures absolutely do not. Dimming each light to two-thirds is a common way to make it work.
The wattage math stays the same, but real-world voltage drop and heat rise in long cords, and a cheap power strip without a proper breaker will get hot long before the wall breaker trips. Any single cord over 25 feet deserves a heavier gauge; the extension-cord voltage-drop calculator goes deeper.
Almost always there is something else on the circuit you have not counted — a refrigerator compressor, a space heater, an aquarium pump. Turn everything else off and see if the trip persists; if it does, an electrician should look at the breaker itself, since worn thermal breakers trip early on a fully safe load.
Chlorova Gardening Team
Builds, checks and documents every tool we publish
Chlorova editorial review
Checked against extension-service publications
Daily light integral from PPFD and hours — and the runtime or intensity a crop needs.
Use ToolSeed per tray, expected yield and cost per pound for a microgreen grow.
Use ToolVoltage lost along a garden or grow-room extension cord, by gauge, length and amps.
Use Tool